20 TC, 2 RTD, 4 Signal Inputs, 6 Relay Outputs Controller, 2 CAN, Ethernet

The Temperature Scanner monitors up to 20 thermocouples and 2 RTDs to provide the temperature information to the engine control system over CAN bus. The thermocouple channels are independently configurable for type B, E, J, K, N, R, S, or T thermocouples. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All 20 channels of temperature data are automatically sent over the CAN bus when power is applied with no additional programming or configuration required. 2 independent RTD channels are available for Pt100 sensor inputs with 2 or 3-wire connections. There are 4 universal signal command inputs. The control sets 6 Form C relay outputs. Integral diagnostics determine thermocouple integrity. 3-way isolation is provided for the CAN line, inputs, and power supply. The two CAN channels are fully isolated from one another in the hardware which allows for different CAN networks to be connected. In the software, each will also act independently where incoming or outgoing messages can be configured to receive or send on a specific CAN channel. Modbus TCP/IP communications are also available. The scanner is enclosed in a rugged IP67 rated enclosure with an 86 pin TE Deutsch connector.

20 TC, 2 RTD, 4 Signal Inputs, 6 Relay Outputs Controller, 2 CAN, Ethernet

The Temperature Scanner monitors up to 20 thermocouples and 2 RTDs to provide the temperature information to the engine control system over CAN bus. The thermocouple channels are independently configurable for type B, E, J, K, N, R, S, or T thermocouples. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All 20 channels of temperature data are automatically sent over the CAN bus when power is applied with no additional programming or configuration required. 2 independent RTD channels are available for Pt100 sensor inputs with 2 or 3-wire connections. There are 4 universal signal command inputs. The control sets 6 Form C relay outputs. Integral diagnostics determine thermocouple integrity. 3-way isolation is provided for the CAN line, inputs, and power supply. The two CAN channels are fully isolated from one another in the hardware which allows for different CAN networks to be connected. In the software, each will also act independently where incoming or outgoing messages can be configured to receive or send on a specific CAN channel. Modbus TCP/IP communications are also available. The scanner is enclosed in a rugged IP67 rated enclosure with an 86 pin TE Deutsch connector.

20 TC, 2 RTD, 4 Signal Inputs, 6 Relay Outputs Controller, 2 CAN, Ethernet
Parts

Showing the single result

P/NPart NameAdd to Quote
AX18080020 TC, 2 PT100 RTD, and 4 Universal Inputs, 6 Relay Outputs, 2 SAE J1939, Ethernet TCP/IP